CR003 LF EM4200 EM4100 TK4100 4100D UART WG26/WG34 moduli ya msomaji 3v au 5V
Taarifa za Msingi
25khz LF RFID Reader Moduli EM4200 EM4100 TK4100 UART / Hali ya Weigand
CR003 ni moduli ya 125K ya kusoma pekee ya EM4200 EM4100 TK4100 UART au Hali ya Weigand ambayo ina toleo la 3v au 5v na kwa ukubwa wa DIP28.
Sifa za Kiutendaji na Kimwili
Jina | Moduli ya Kisomaji cha CR003 cha Ukaribu | |||
Uzito | 12g | |||
Vipimo | 40mm(L)x20mm(H)x8mm(W) | |||
Halijoto | -40一s+85C | |||
Kiolesura | COMS UART au WG | |||
Soma Masafa | hadi 8-12 cm | |||
Mzunguko | 125KHZ | |||
Inafaa Kwa | uEM 4001 au sambamba | |||
EM4200,EM4100,TK4100,HT4168,4100D | ||||
Mahitaji ya Nguvu | DC3.0- 5.5V ,30ma - 50ma | |||
MCU | CPU 51-8bit |
Maelezo ya Pini & Miundo ya Data ya Pato
PinNo. | Maelezo | CR003T (ASCII) | CR003W(Wiegand) | CR003M | CR003A(ABAⅡ) |
Pini 1 | D1 | Pato la Data la TTL(Tx) | Pato la DATA1 | Pato la DataMsimbo wa Manchester | Pato la DATA |
Pini 2 | D0 | NC | Pato la DATA0 | NC | CLK |
Pini 3 | CS | NC | NC | NC | CP |
Pini 4 | GND | GND | |||
Pini 5 | VCC | NGUVU(+4.6V - +5.4V DC) | |||
Pini 15 | ANT1 | Kwa Antena (L1=1000uH) | |||
Pini 16 | ANT2 | Kwa Antena | |||
Pini 26 | GND | GND | |||
Pini 27 | VCC | NGUVU(+4.6V - +5.4VDC) | |||
Pini 28 | BEEP/LED | BEEPER/LED | BEEPER/LED | NC | BEEPER/LED |
* Pin28 ni PEEPER/LED Driver, baada ya Data output , Pin28 imewekwa chini
CR003W01 = Wiegand26
CR003W02 = Wiegand26/34 Switch
CR003W03 = Wiegand34
Miundo ya Data
CR003T-01Muundo wa Data ya Pato– ASCII(RS232.TTL) 9600bps,N,8,1
STX (02H) | DATA(10 ASCII) | LRC (2 ASCII) | CR | LF |
ETX (03H) |
[The 1byte (2 ASCII charaters) , LCR ni Longitudinal Redundancy Check.]
Kwa mfano:DATA : 62H E3H 08H 6CH EDH,LRC: (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH)=08H,Pato: 0X02 0X36 0X32 0X45 0X33 0X30X3040 40X30 4 4 30 4 30 4 4 30 4 4 30 4 40 4 4 30 4 4 X30 0X38 0X0D 0X0A 0X03
CR003T-02Muundo wa Data ya Pato– ASCII(RS232.TTL) 9600bps,N,8,1
STX (02H) | DATA(10 ASCII) | LRC (1BYTEI) | ETX (03H) |
[The 1byte (2 ASCII charaters) , LCR ni Longitudinal Redundancy Check.]
Kwa mfano:DATA : 62H E3H 08H 6CH EDH,LRC: (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH)=08H,Pato: 0X02 0X36 0X32 0X45 0X33 0X30X3040 40X30 4 4 30 4 30 4 4 30 4 4 30 4 40 4 4 30 4 4 X08 0X03
CR003T-03Muundo wa Data ya Pato– ASCII(RS232.TTL) 9600bps,N,8,1
DATA(10 ASCII) | CR |
[The 1byte (2 ASCII charaters) , LCR ni Longitudinal Redundancy Check.]
Kwa mfano:DATA : 62H E3H 08H 6CH EDH,
Pato: 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X0D
CR003WMuundo wa Data ya Pato, Kwa Mfano: Wiegand 26 bit
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 |
P(1) | E | E | E | E | E | E | E | E | E | E | E | E | O | O | O | O | O | O | O | O | O | O | O | O | P(2) |
HATA Usawa(E) | Usawa wa ODD(O) |
P(1):Parity Start Bit, 2-13 bit EVEN Parity bit
P(2):Parity Stop Bit, 14-26 bit ODD Parity bit
Weigand
Muundo wa data: